Honeywell Gas Valve Actuator, V4062A1198

Honeywell Gas Valve Actuator, V4062A1198
Code: ACT-V4062A1198
Price: $731.74
Quantity in Basket: None
Quantity:
Manufacturer: Honeywell

V4062A, B, D Hi-Lo-Off Fluid Power Gas Valve Actuator

The V4062 Gas Valve Actuator in combination with a V5055, VE5000¹ or V5097 Gas Valve provides three-position control of the gas supply to commercial and industrial burners.

Features
• When energized, the V4062 Actuator opens the V5055/VE5000/V5097 Gas Valve to the low-fire position. The actuator opens the valve to the fully open position when the line voltage contacts are made.
• When used with the V5055, V5097 or VE5000¹ Gas Valve, the combination is rated for final safety shutoff service. Although the V4062 can be used with all V5055 or V5097 Valve models, the V5055/V5097B with characterized guide is recommended for optimum control and low-fire repeatability.
• The standard model has an opening time of 26 seconds at 60 Hz, or 32 seconds at 50 Hz. A fast-opening model is available, with timings of 13 seconds at 60 Hz, or 16 seconds at 50 Hz.
• Maximum closing time is one second, which meets code, standard, insurer requirements.
• Damper shaft models are available with or without spring return; shaft extends out both sides and rides in Delrin bushings; used with standard damper crank arm (part no. 7616BR).
• Red OPEN indicator attached to the actuator stem shows when the valve is even slightly open; yellow SHUT indicator on the valve stem shows only when the gas valve is fully closed.
• Ambient temperature range is -40° to 150°F (-40° to 66°C) for 60 Hz models; -10° to 158°F (23° to 70°C) for 50 Hz and 50/60 Hz models.
• Models available with factory adjusted, field-adjustable, single-pole-double throw (spdt) auxiliary switch rated at 1/2 hp (0.37 kW). Auxiliary switch can be added in the field.
• Low-fire position is adjustable with adjusting wrench, part no. 135796 (included with the actuator).
• Standard enclosure meets NEMA 1 (IP30) general purpose requirements.
• V4062/V5055C,E and V4062/V5097C,E combinations available with a proof-of-closure switch and double valve seal (valve seal overtravel interlock) to meet specific code/standard/insurer requirements.
• Model available to be used with series 60 floating type controller.
• Model available with adjustable maximum flow switch.

¹VE5000 is a European manufactured and approved valve for European use only.

Specifications
Important: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.

Models:
• V4062A HI-LO-OFF Gas Valve Actuator.
• V4062B HI-LO-OFF Gas Valve Actuator, high pressure.
• V4062D HI-LO-OFF Gas Valve Actuator with proof-of-closure switch. Use with V5055/V5097C,E (double seal) gas valves for valve seal overtravel interlock. Do not use V4062 with V5034 Valve body.

Electrical Ratings: Standard V4062A, D Actuators
• 60 Hz, 26 second opening
• 50 Hz, 32 second opening
Voltage/Frequency
Opening
Holding
W
VA
W
VA
120V/60 Hz
59.5
129
19.0
28.0
100V/50-60 Hz
53.0/42.7
105/80
20.0/17.2
33/29
200V/50-60 Hz
72.01/52.5
160/110
1/.4/16.2
28/24

Electrical Ratings: Fast-opening V4062A, D Actuators
• 60 Hz, 13 second opening
• 50 Hz, 16 second opening
Voltage/Frequency
Opening
Holding
W
VA
W
VA
120V/60 Hz
59.5
129
19.0
28.0
220V/50 Hz
84.0
196
17.0
27.0
220V/50 Hz
82.0
180
16.5
26.4
220-240V/50-60 Hz¹
74.5
143.5
13.7
24.8
220-240V/50-60 Hz²
61.9
112
11.2
20.5
¹ 230V, 50 Hz power supply.
² 230V, 60 Hz power supply.

Electrical Ratings: Fast-opening V4062B Actuators
• 60 Hz, 13 second opening
• 50 Hz, 16 second opening
Voltage/Frequency
Opening
Holding
W
VA
W
VA
220-240V/50-60 Hz¹ 76.5
150.6
13.3
28.8
220-240V/50-60 Hz² 64.4
118.2
11
23.2
¹ 230V, 50 Hz power supply.
² 230V, 60 Hz power supply.

Pressure Ratings of Valve-Actuators Combinations
Valve
V4062A, D¹ V4062B
Differential² Closeoff³ Differential² Closeoff³
psi
mbar
psi
bar
psi
mbar
psi
bar
V5055A,C; V5097A,C 3/4 to 3 in.
5
340
15
1
15
1000
15
1
V5055A,C 4 in.
3
200
15
1
5
340
15
1
V5055B, V5097B 3/4 to 3 in.
5
340
15
1
15
1000
15
1
V5055B 4 in.
3
200
5
1
5
340
15
1
V5055D,E, 3/4, 1, 1-1/4, 1-1/2; V5097D 3/4 in. to 2 in.
5
340
75
5
25
1700
75
5
V5055D,E; V5097D,E 2, 2-1/2, 3 in.
5
340
45
3
15
1000
45
3
¹ Use a V4062D (with proof-of-closure switch) with a V5055/V5097C or E (with double seal) for valve seal overtravel interlock.
² Maximum operating pressure differential.
³ Maximum closeoff pressure without seal leakage. This is the maximum allowable pressure drop to which a valve may be subjected when fully closed, and is independent of the valve body rating.

Replaces Part Number: V4062A1198

XMN

CF